Osburn OB01601 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pour la maison Osburn OB01601. Osburn OB01601 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
READ AND KEEP THIS MANUAL FOR REFERENCE
45084A
Printed in Canada 12-06-2015
OWNER’S MANUAL
1600 INSERT (OB01601 model)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED WOOD
INSERT
OREGON DEPARTEMENT
ENVIRONMENTAL QUALITY
Verified and tested following
ULC S628, UL 907, UL 1482 Standards by an
accredited laboratory
Manufactured by: STOVE BUILDER INTERNATIONAL INC
.
250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3
After-sale service: 418-908-8002 E-mail: tech@sbi-international.com
www.osburn-mfg.com
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time to
time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - 1600 INSERT (OB01601 model)

READ AND KEEP THIS MANUAL FOR REFERENCE 45084A Printed in Canada 12-06-2015 OWNER’S MANUAL 1600 INSERT (OB01601 model) US ENVIRONMENTAL PRO

Page 2 - TABLE OF CONTENTS

10MINIMUM MASONRY OPENING, CLEARANCES TO COMBUSTIBLES, AND FLOOR PROTECTOR

Page 3 - INTRODUCTION

11 MINIMUM MASONRY OPENING MAXIMUM STANDARD FACEPLATE MAXIMUM LARGE FACEPLATE F 22.125" (562 mm) 29" (737 mm) 32" (813 mm) G 2

Page 4 - TECHNICAL SPECIFICATIONS

12VENTING REQUIREMENTS The flue is a critical component to a satisfactory installation. Your insert will attain its best performanc

Page 5 - INSTALLATION

13INSTALLATION INSTRUCTIONS 1. Inspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or upgra

Page 6 - DOOR OVERLAY INSTALLATION

144. POSITIONING THE UNIT: The more extended the insert, the greater the heat transfer to the room. When installed as an extended inse

Page 7 - DOOR ADJUSTMENT

155. If lag-bolts and anchors are to be used to secure the insert, the hole locations should be marked with the unit in place. Remove

Page 8

167. INSTALLATION ON FACEPLATE: Attach the mitred corners of trim together using the corner brackets. Slide the assembled trim over the edge of th

Page 9

1710. Push the air control (A) in, all the way. Slide the adjustable faceplate sleeve back into its original location until the faceplate fi

Page 10 - FLOOR PROTECTOR

18OPERATION Your heating unit was designed to burn wood only; no other materials should be burnt. Wastes and other flammable materials should n

Page 11

19Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split. The wood should not be stored directly on the gro

Page 12 - VENTING REQUIREMENTS

2 TABLE OF CONTENTS TECHNICAL SPECIFICATIONS ... 4 INSTALLA

Page 13 - INSTALLATION INSTRUCTIONS

20HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for

Page 14

21CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moistur

Page 15

22MAINTENANCE Your OSBURN insert is a high efficiency insert and therefore require little maintenance. It is important to perform a visual inspection

Page 16

23BAFFLE INSTALLATION All firebrick and ceramic wool baffles must be properly in place for correct burning operation. Have any dama

Page 17

24SECONDARY AIR TUBE REPLACEMENT 1. Remove cotter pin at left end of tube. 2. Slide tube to right and lower tube end below left plenum. 3. Slid

Page 18 - OPERATION

25 OSBURN LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This w

Page 19

3 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wi

Page 20 - RELOADING

4 TECHNICAL SPECIFICATIONS Combustible: Wood Recommended surface: Up to 1800 square feet Heating Capacity* : E.P.A :

Page 21 - ASH DISPOSAL

5 INSTALLATION SAFETY NOTICE • IF THIS INSERT IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLAT

Page 22 - MAINTENANCE

6 DOOR OVERLAY INSTALLATION In order to complete the assembly of your Osburn 1600 wood insert, you need to install the door overlay. See figure 1 be

Page 23 - BAFFLE INSTALLATION

7 DOOR ADJUSTMENT In order for your insert to operate properly, the door should be adjusted periodically to provide an air tight fit.

Page 24 - Model Type of tube

8 PRE-INSTALLATION REQUIREMENTS MASONRY & ZERO CLEARANCE REQUIREMENTS The masonry fireplace must meet the minimum code requirements, or NFPA 21

Page 25

9 4. CHIMNEY CAPS: Mesh type chimney caps must have provision for regular cleaning, or the mesh should be removed to eliminate the potential of plu

Commentaires sur ces manuels

Pas de commentaire